The Cartesion Prime SP- Digital TOF PET Detector
Chart The Right Clinical Course- Combining years of product development with the latest digital PET innovations, we’ve created a system that delivers exceptional image quality at high speed with accurate quantification and low dose. Providing innovative and sustainable Digital TOF PET-CT solutions that enhance your business and patient outcomes.
Deep Learning Reconstruction (DLR) development for medical imaging, as evident by the successful release of Advanced intelligent Clear-IQ Engine (AiCE) for CT, PET, and MR. And now, the second generation of AiCE for PET, AiCE-integrated (AiCE-i), offers three pre-trained DCNN with different levels of smoothing to meet different user preferences. AiCE-i yields excellent performance by improving image quality and denoising PET images.
The use of SiPM photosensors has inspired new design choices that can impact image quality, scan times, and dose efficiencies, which all lead to better patient care. Because there are many ways to design a PET detector with SiPM, the ability of a PET detector to maximize this impact goes beyond just including SiPM. Canon Medical has designed the new Cartesion Prime SP Digital TOF PET-CT detector to leverage the potential of SiPM photosensors while taking full advantage of the design of the entire PET detector from coverage to cooling.
The Cartesion Prime SP PET-CT is designed to address many aspects of the patient experience that focuses on comfort during the scan process. The scanner includes a wide 78 cm bore with a flared gantry design, as well as a wide patient couch that creates a more open and comfortable environment. With a low minimum scanner bed height patients will be able to more easily and safely navigate getting on and off the scanner bed when assistance is needed.
* Option.
1 PIQE is designed to fully utilize the maximum resolution of the detector.
2 Optimization of injected dose is only recommended within the dosing ranges that appear in approved drug labeling.
3 Based on an ALD evaluation of 240 3D Landmark scans (40 Head, 200 Body) 3D landmark scan data. Cases in which the relevant anatomic landmark(s) were not present (9) were excluded. 97% accuracy is based on results within +/- 1cm of target start, end, and FOV position, confirmed by two experienced CT Technologists.
At just 22.4 m², Cartesion Prime SP is space efficient Digital TOF PET-CT system that fits in a smaller installation space and gives you more room to work in.